v6.0.0 is not the latest firmware for the SmallHD PageOS: the current version is v6.4.0 (September 30, 2026). Go to v6.4.0
What's in this update
Supported series: FALCON - 500 Series, FALCON - 700 Series, FIAT - 700 Series, FOCUS - 700 Series, Other Services, Others Important Software Information: PLEASE READ BELOW
- OLDER FIRMWARE IS LISTED BELOW, CLICK “SHOW MORE”
- This firmware will NOT support the following monitors:
- 2403 HDR & 2403 HB
- 1703 HDR & 1703 Studio
- 1303 Studio
- 700 Series - 701, 701L, 702 Bright, 702 OLED
- 500 Series - 501, 502, 502 Bright
- This firmware is NOT compatible with the DSMC3 RED®Touch, or Action 5
- RED® Touch users have firmware available on the RED® Touch tab
- This firmware is NOT compatible with legacy monitors (DP1, DP6, DP4, AC7, and
DP7-PRO)
- If your firmware is below 3.6.5, we recommend the following upgrade path: 3.6.5 -> 4.8.7 -> 5.5.6 -> 6.0.0 Features Added:
- Allow 4K Production Monitor tally/record indicator to be controlled via GPI connection
- Added support for multiplexed SDI inputs
- Support 2x6G and 4x3G 2SI encoded inputs
- Monitors are now compatible with several USB Wifi adapters
- Added support for Level B SDI Video for 4K Production Monitors
- Waveform tool added to the Quantum 32
- Sony BURANO + Sony FX6 Camera Control Support (Cine 5, Cine 7, Ultra 7, Ultra 10, Cine 13, Cine 18, Cine 24, Vision 17, Vision 24, OLED 22, OLED 27, Quantum 32)
- Added Dual View to Ultra7
- Added support for Calman integration to Quantum 32
- Added support for a new Vision algorithm (Vision 17, 24)
- Improves highlight rendering
- Improves HDR accuracy and optimizes backlight Improvements and Alterations:
- Slight improvements to Vectorscope FPS and Image Capture speed
- Updated some UI animations
- Page transition speed is now faster
- Monitor Settings > Interface > Pages
- Added support for a custom bouncing “No Video” icon
- Monitor Settings > User > Personalize
- Luminance Color Pipe Rework
- “Backlight” and “Brightness” has been replaced with the word “Luminance”
- Luminance may now be configured within a Color Pipe
- Color Pipe UI Update
- The Color Pipe UI has been updated to make the system easier to use
- The Crosshatch Tool now allows creating a denser grid
- Improved the granularity of the Zebra thresholds
- Thresholds may now be set based based on either code values or IRE
- Allow capturing two images at once, one with and one without any compatible tools
- Custom Exposure Assist Improvements
- Users may now change the background of a custom exposure map
- Options include: Grayscale, Transparent (Clean), or Spectrum
- Allow users to load custom exposure maps as an image file (1024 wide .png) from removable media
- Color Pipes now support the following additional white points: D93, D56, D60
- When function button tools are deactivated, they are removed from the toolbar
- Manual Adjustments may now be tuned per-Color-Pipe
- By default, everything will work as it did in previous versions
- Calibration settings menu now has an option to enable “manual adjustment sets”
- When exposed, there will be 8 sets of manual adjustments that may be configured on the monitor. Factory and User calibrations must each be assigned to one of those 8 sets
- Color Pipes may also be assigned to a manual adjustment set. By default, each Color Pipe will use the manual adjustment set of the current calibration. However, they can be configured to instead override that value with a different set of manual adjustments
- Function Button Tooltips now indicate function state (on vs off)
- Exposure Assist legend may now be placed vertically
- Opening the Studio Brightness menu no longer automatically displays a white patch
- Adjusted the EL Zone scale, replacing the colors of white and black with light red and dark purple
- Allow users to alter the record tally UI element’s appearance in the Metadata tool Bugs Fixed:
- Fixed bug causing User Conversion LUTs in Color Pipes to be applied incorrectly
- Resolved audio data from a BlackMagic PIX-E5 not being detected by SmallHD monitors
- Resolved interactions between the Input Tool and Image Capture on Record Start
- Camera Control - Scrubbing in playback mode on ARRI cameras no longer changes Pages
- Fixed a case of incorrect Color Pipes being applied to Multi Pages, when more than one multi-view page was present on the monitor.
- Resolved flickering on a Multi Page when receiving some PsF formats
- Fixed issues with 8 channel SDI Audio on 4K production monitors
- Fixed audio issues when more than 8 channels are present
- Super Pixel Scaling was not working, monitors continued to use interpolation
- Resolved video range issues that came about when different Color Pipes were assigned different video ranges
- Resolved discrepancies between Color Picker and Exposure Assist
- Restored the missing “Burn-in Recovery” settings element
- Lock Switches now function after reboot
- Focus Assist lines now persist after a reboot
- Focus Assist now functions correctly when bound to a function button
- Fixed rare instances of legal range video not being displayed correctly in calibration wizard
- On 4K Production Monitors, Image Overlay no longer dims the image when the source media is removed
- Fixed Low Voltage Warning sometimes not appearing
- General UI improvements
- Fixed several video format issues
- Ultra 5 TX Output toggle no longer causes wireless video issues
- Image Overlay no longer obscures aspect and safe guides
- Activating Image Capture no longer causes the color picker tool to deactivate
KNOWN (EXISTING) ISSUES
- Waveform does not work at 1080p60 on 4K production monitors
- Quantum 32 Panel Turns Off when hot-swapping batteries
- Workaround: Avoid removing the active battery, remove only the drained battery
- Quantum 32 panel is too dim on boot
- Workaround: Toggle any luminance setting after a reboot
- Connecting to an ARRI Alexa camera via camera control may crash the monitor when using DHCP
- Only applies when direct-connecting to a camera, not when using a router
- Workaround: Set the monitor’s static IP address prior to connecting