QRP Labs QMX

QRP Labs QMX firmware

QRP Labs · QMX · QMX · HF transceiver

Latest firmware for the QRP Labs QMX is v1_04_015 (September 24, 2026).

QMX firmware changelog

  1. v1_04_014 v1_04_015

  2. v1_04_013 v1_04_014 Fixes CW preset messages, SWR screen display and control, and SSB CAT mode keying.

  3. v1_04_012 v1_04_013

  4. v1_04_011 v1_04_012

  5. v1_04_010 v1_04_011 Adds CW TX indicator, fixes Practice Mode issues, and resolves display problems with GPS, SWR, and SSB calibration.

  6. v1_04_009 v1_04_010 CW message truncation fixed and Virtual U3S frequency issues resolved; symmetric phase wrap now ON by default.

  7. v1_04_008 v1_04_009

  8. v1_04_007 v1_04_008

  9. v1_04_006 v1_04_007

  10. v1_04_005 v1_04_006

Firmware history

All versions below were published by QRP Labs on qrp-labs.com. Third-party and modified firmware is never listed.

  1. Version 1_04_015 Latest Released Sep 24, 2026 First seen Sep 25, 2026

    Source: qrp-labs.com

    Show release notes

    Consider this a Beta f​irmware version

    1. Bug fix: SWR Tune showing SWR but was not outputtin​g RF
    2. Bug fix: Radio unlock did not occur properly on keying at speed = 0 (Tune)
    Release notes & download
  2. Version 1_04_014 Released Sep 23, 2026 First seen Sep 24, 2026

    Fixes CW preset messages, SWR screen display and control, and SSB CAT mode keying. — summary by updatemystuff.com

    Source: qrp-labs.com

    Show release notes

    Consider this​ a Beta firmware version

    1. Bug fix: SSB mode not keyed properly from CAT TX; RX; command (Winlink etc)
    2. Bug fix: SWR screen in terminal, 'T' started TX but it did not end after 0.5s and no SWR display
    3. Bug fix: SWR Tune on LCD, exit during TX th​en re-enter didn't clear the underline
    4. Bug fix: CW keying entry of preset messages was not working
    Release notes & download
  3. Version 1_04_013 Released Sep 22, 2026 First seen Sep 23, 2026

    Source: qrp-labs.com

    Show release notes
    1. Bug fix: Tune mode on Sp​eed=0 CW, caused permanent key-down, required power cycle
    2. Bug fix: SWR Tune in​ Hardware menu, underline under 'A' didn't go after TX stopped
    Release notes & download
  4. Version 1_04_012 Released Sep 21, 2026 First seen Sep 22, 2026

    Source: qrp-labs.com

    Show release notes
    1. Bug fix: DiGi mode always reported​ insufficient audio
    2. Bug fix: SWR Tune and other H​ardware Tests menu items on LCD froze
    Release notes & download
  5. Version 1_04_011 Released Sep 19, 2026 First seen Sep 20, 2026

    Adds CW TX indicator, fixes Practice Mode issues, and resolves display problems with GPS, SWR, and SSB calibration. — summary by updatemystuff.com

    Source: qrp-labs.com

    Show release notes
    1. TX indicator now shown on key-down in CW mode
    2. Clean-up of "Practice mode" in CW Keyer menu. Now clear​ly only applies to CW, everywhere
    3. LPF and SWR Sweeps, and Diagnostics screen, run properly even when CW Practice Mode enabled
    4. Major clean-up of multi-terminal functionality (locking etc)
    5. Bug fix: Virtual GPS stats display t (tracked sats) and s (SNR) could be incorrect
    6. Bug fix: CW Message playback didn't work when Pr​actice mode is on
    7. Bug fix: Don't recalculate WSPR encoding in the case of a change in GPS locator (vU3S does it)
    8. Bug fix: Don't stop SWR Tune display when a CAT character is received
    9. Bug fix: SSB calibration graph titles no longer hidden when there's no calibration data
    Release notes & download
  6. Version 1_04_010 Released Sep 14, 2026 First seen Sep 15, 2026

    CW message truncation fixed and Virtual U3S frequency issues resolved; symmetric phase wrap now ON by default. — summary by updatemystuff.com

    Source: qrp-labs.com

    Show release notes
    1. Symmetric phase wrap is now ON by default after a factory reset
    2. Bug fix: 2nd and subsequent CW message sending lost th​e first part of the message
    3. Bug fix: interval between CW message repeats decreased at double rate in some cases
    4. Bug fix: Where a CW message caused SWR protection, canceling SWR protection resumed message
    5. Bug fix: Pixel duration calculated in​correctly in U3S "Custom" pattern mode
    6. Bug fix: CAT not reporting correct frequency during Virtual U3S operations
    7. Bug fix: QMX not returned to normal operating frequency during gaps between Virtual U3S TX
    8. Bug fix: Virtual U3S RX mode not receiving on stated frequency
    9. Bug fix: Virtual U3S displayed band LPF number was incorrect (one TX slot behind)
    Release notes & download
  7. Version 1_04_009 Released Aug 30, 2026 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Bug fix: Accide​ntally WSPR was transmitted 250 Hz t​oo low - now it's correct
    Release notes & download
  8. Version 1_04_008 Released Aug 27, 2026 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Bug fix: Virtual U3​S Frame parameter could not be more than 30
    2. Added all remaining U3S modes ​to Virtual U3S
    3. Added RTTY to Virtual U3S (not available in real U3S)
    Release notes & download
  9. Version 1_04_007 Released Aug 14, 2026 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Bug fix: Fixed the 160m image rejection (90-degree quad LO phase relationship on 160m​)
    2. Bug fix: Image Sweep screen had incorrect result first time it ran
    3. Bug fix: Sending stored CW message wrote frequency to 00,000,000
    4. Bug fix: Fixed continuous key-down between stored message repeats
    5. Bug fix: 'M' in practice mode character was not displ​ayed during stored message play
    6. Bug fix: '006 had re-introduced leading edge CW RF spikes 50% of the time (another race condx)
    Release notes & download
  10. Version 1_04_006 Released Aug 12, 2026 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Show S-meter in Digi mode
    2. Bug fix: TX underlines the correct VFO indicator character now in B and Split m​ode
    3. Bug fix: Prevent occasional CW glitch due to race condition in the microsecond timer
    4. Virtual U3S adds: WSPR15, CW, CW ​ID, FSK, FSKCW, QRSS, DFCW, Slow Hell, Hell, DX Hell
    5. GPS Protection disabled when not in CW mode or when internal GPS (QLG3 in QMX+) selected
    Release notes & download
  11. Version 1_04_005 Released Aug 6, 2026 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Bug fix: removed​ spike on first dit after power-up
    2. Bug fix: PA mod test (and other functions) did not work until after a dit or 'T' in diag
    3. ​Bug fix: CAT GP command had reversed longitude sign
    4. Reduced current spike on key-down
    Release notes & download
  12. Version 1_04_004 Released Jul 23, 2026 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Added option in Power menu to set full scale deflection to 12W - useful for 4:4 PA mod
    2. New CAT command GP returns GPS position and date and time
    3. New CAT command ​SR returns SWR protection status and can reset it
    4. SMPS Bias circuit pre-warm up at radio power up
    5. CW menu: added choice of CW shaping envelope, and rise/fall times
    6. Bug fix: Removing leading edge spike on CW key-down
    7. Bug fi​x: Semi QSK CW keyed 2nd and subsequent dits even when TX disabled in Band Config
    8. Bug fix: Certain menu items that should be editable as 1 digit, allowed two
    Release notes & download
  13. Version 1_04_003 Released Jul 18, 2026 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. CAT new command UI gets 24-character unique serial number of the STM32 chip
    2. CAT new commands BU, BD for Band Up, Band Down
    3. CAT new command BN get/set the band from/to the column number of the Band Config table
    4. 'E' symbol on no or insu​fficient digi mode audio is delayed 0.5 seconds to avoid concern
    5. Bug fix: Errors with CAT MM commands for list values like EQ global gain
    6. Bug fix: CAT MM for returning display delimiter didn't return it.
    7. Bug fix: CAT MM is​sues with CW Center frequency due to pointing at wrong list
    8. Bug fix: Error reporting and actions on Virtual U3S fixed
    9. Bug fix: Output RF when Practice mode on and Semi QSK enabled
    10. Bug fix: Stored message sending couldn't be stopped by a dit or dah press
    11. Bug fix: Prevent GPS streaming to a port configured at not more than 9600 baud
    12. Bug fix: 1pps Heart icon was not displayed correctly in U3S screens
    Release notes & download
  14. Version 1_04_002 Released Jun 18, 2026 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes

    Beta firmware version NOTE: Installing​ this firmware executes a Factory Reset: be sure to select your correct firmware version after the reset, at the prompt, by rotating Tune knob, then pressing the menu button or Tune knob button.

    1. Bug fix: SWR Style could be incorrect if EEPROM contents not set up
    2. Bug fix: Virtual U3S not stoppable by pressing any button, had to cycle power
    3. Bug fix: Virtu​al U3S did not transmit properly
    4. Bug fix: Virtual U3S missing PPS "heartbeat"
    5. Bug fix: Virtual U3S Maidenhead grid locator display error
    6. Bug fix: Repeated CW message sending omitted first part of message
    Release notes & download
  15. Version 1_04_001 Released Jun 12, 2026 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes

    BETA firmware version

    1. Bug fix: 1_04_000 hung when ru​n on a QMX, but was OK on QMX+
    2. Bug fix: AM mode indicator incorrect when using character type mode indicator
    3. Bug fix: Add AM (mode 5) to CAT MD command Get/Set
    4. Bug fix: Resolved distorted TX audio in LS​B mode when Symmetric phase switched on
    5. Bug fix: CAT MU command and MM (when auto update enabled) loaded previously saved state (VFO etc)
    6. Bug fix: On first installing 1_04_000, hung with message "Radio load"
    7. Bug fix: Virtual U3S would not run
    Release notes & download
  16. Version 1_04_000 Released May 8, 2026 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes

    Beta firmware version: Use only on QMX+ it does not work on QMX Documentation is pending. Details are in the QRP Labs groups.io forum here .

    1. Added AM mode experimentally, currently receive only, with 150-3200 Hz filter
    2. Virtual U3S: complete Ultimate3S in a QMX - see separate manual
    3. LCD/buttons UI now supports editing grid screens such as Band Configuration
    4. Glitchy supply protection saves SMPS modules
    5. Fullscreen CW practice decode modes (line and ​character scroll)
    6. System config menu "Modes enabled" setting lets you choose what modes to enable for the radio
    7. Optional setting "SWR warn style" allows inverted 's' or flashing inverted 's'
    8. Flashing normal/inverted 'E' error on Digi mode when no audio or insufficient audio
    9. SSB config menu re-arrangement: all mic items in microphone sub-menu, likewise for USB audio
    10. SSB new menu item "Symmetric phase" improves performance - recommend setting: YES
    11. SSB transmit polar modulation CPU speed improvement
    12. New parameter "PTT from DTR" lets Virtual COM port DTR operate USB audio SSB transmit PTT
    13. CAT configuration items moved to a submenu
    14. CAT new configuration menu item "CAT MM effect" to control whether updates are on demand or immediate
    15. CAT new command MU forces a complete config menu reload
    16. CAT new command KD for get/set key-down state
    17. CAT mew commands TR and RR to set/get Tune Rate and RIT Rate respectively.
    18. CAT new command PS for power supply status; read returns 1, and PS0; shuts down
    19. CAT new command AI for Auto Info (modes Old, Extended, Both)
    20. CAT MD8; c​ommand puts QMX into SWR Tune mode (MD0; exits)
    21. Bug fix: Semi-QSK mode, TX signal high during key-up, caused high current in 2 of 4 transistors
    22. Bug fix: Adjusting volume while in config menu messed up the screen a lot
    23. Bug fix: When RIT was enabled, Volume change timeout moved focus to main tuning
    24. Bug fix: Pressing volume button at the same time as rotating it could cause buttons to lock up
    25. Bug fix: When RIT was enabled, long press menu button did not enter menu
    26. Bug fix: CW Keyer key from DTR only worked for USB port 1
    27. Bug fix: Triple click to toggle backlight persists until power cycle or menu change
    28. Bug fix: CAT command PC only returned two digits when power >= 10W; now returns 3 digits then
    29. Bug fix: CAT MM commands stripping floating point decimal point when thousands delimiter is .
    30. Bug fix: CAT MM CW Bandwidth and center commands had to be issued twice to take effect!
    Release notes & download
  17. Version 1_03_002 Released Feb 7, 2026 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes

    CAT programming manual

    1. Bug fix: DTR keying would only wor​k on USB 1, not on 2 or 3
    2. USB audio monitor during SSB transmit, volume adjustable in SSB menu
    3. Remove spurious 1.00000 on terminal bottom left, on releasing PTT in SSB ​TX
    4. Bug fix: PTT_P was ON by default at power-up, until first TX occurred
    5. Bug fix: Removed loud pop when changing bands
    Release notes & download
  18. Version 1_03_001 Released Feb 6, 2026 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes

    CAT programming man​ual

    1. Bug fix: Removed "nan" in "Max PA Voltage" setting on upgrading to 1_03_000
    2. Bug fix: Fixed hanging when handling VFO mod​es or Tune rates etc., in VFO menu
    3. Bug fix: Editing issue with floating point parameters (Max PA Voltage) on LCD
    Release notes & download
  19. Version 1_03_000 Released Feb 6, 2026 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Keying from USB Virtual COM DTR signal (N1MM, fldigi etc)
    2. Option to display mode as a character (C, D, U, L) not graphic; see D​isplay/Controls menu
    3. Menu "Strght mode" renamed "Straight mode"; and "Sidetone frq" renamed "Sidetone freq."
    4. Double-click default increased to 500; sensible defaults (20) for Band and Volume Change timeouts
    5. New parameter in VFO menu specifies max denominator value for the continued fraction
    6. New CAT command PL for Get/Set of Receive PLL parameters
    7. Display option for numeric S-meter, Power meter, SWR meters instead of the bar graph
    8. Protection menu now has max PA voltage setting to protect​ the PA from high supply voltages
    9. Add Reverse power to Diagnostics page
    10. SWR Protection reset options: by button press, timer, or on TX->RX
    11. Accessibility feature: In terminal menu, press Tab then a number to go to that row
    12. Accessibility feature: Simplified terminal menu option
    13. New SSB audio source option "Auto" uses Ext Mic unless CAT switched to TX, then USB audio is used
    14. SideKar CAT connection workaround: sends /0/0/0/003/OM; instead of OM; now ignores characters < 32
    Release notes & download
  20. Version 1_02_009 Released Nov 3, 2025 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Bug fix:​ Serial 6 baud rate (PTT port) wasn't set properly
    2. Bug f​ix: Fault in two-tone test generator fixed!
    Release notes & download
  21. Version 1_02_006 Released Oct 31, 2025 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Bug fix: CAT IF command incorrectly shows VFO B when in TX and in VFO A mode
    2. Bug fix: When changing band up/down the RF Gain doesn't get changed properly
    3. Bug fix: On the LCD, SWR tool now operates correctly at the displayed VFO frequency
    4. Bug fix: TX indicator always under A, even in VFO B and Split ​modes (means not displayed at all in B)
    5. Change "Audio gain (dB)" row name in Band Config to "RF gain (dB)", a more accurate description
    6. New CAT RG command now gets/sets RF Gain (used to be called Aud​io gain, and command AG)
    7. CAT AG command now gets/sets AF Gain, which is Volume, in steps of 0.25 dB e.g. AG083; is 20.75 dB.
    8. System wide update to config handling of boolean parameters to prevent accidental enabling
    9. New CAT ML and MM commands provide complete CAT accessible configuration menu interface
    10. System config submenu "Experimental" for polar modulation SSB experiments (you can't touch this)
    11. Bug fix: CAT Q2 command Set did not work as described (sets VFO A, same as FA command)
    Release notes & download
  22. Version 1_02_005 Released Aug 23, 2025 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Functionality for programming QLG3 E108 module firmware update (fix date​ issue).
    2. Volume time and Band display time are limited to 99 now.
    3. When volume is displayed, pressing any other button o​r tuning cancels the display.
    4. Bug fix: Audo USB/LSB should select USB for 60m band.
    Release notes & download
  23. Version 1_02_004 Released Aug 6, 2025 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Bug fix: CAT IF com​mand incorrect VFO freq when not in VFO A mode
    2. New CAT command TA (transmit audio) e.g. TA1502.34;
    3. New style band selection, allows up or down selection using the volume encoder
    4. Volume display after you adjust it for a configurable time
    5. CAT KY command TS480 compatibi​lity mode
    6. Move factory reset on power up to right button
    7. Auto USB or LSB selection based on band (40m and below are LSB)
    8. Bug fix to GPS time setting, to fix a 1 second time discrepancy that could arise due to GPS timing
    Release notes & download
  24. Version 1_02_003 Released Jun 24, 2025 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Bug fix: streaming GPS ​NMEA data to serial port broke terminal access on othe​r ports
    2. Bug fix: issue in 1_02_002 affecting our factory QMX+ board test only
    Release notes & download
  25. Version 1_02_002 Released Jun 12, 2025 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. System Config / Band version menu item is now read-only 2​. Update version text to QRP Labs, 2025 (was 2024)
    2. Enable QMX+ AUX jack as serial port, including Config menu and baud rate
    3. Enable PTT jack as serial port (requires hardware mmod), config and baud rate
    4. Re-group all serial port settings into their own menu 6​. Capability to stream GPS NMEA data to any serial port
    5. Add CAT command OM: radio model number (QRP Works SideKar compatibility)
    6. Add CAT command TB: retrieve decoded CW text buffer (QRP Works SideKar compatibility)
    Release notes & download
  26. Version 1_02_001 Released Jun 11, 2025 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. SSB Calibration shapes the RF envelope to avoid hard keying causing voltage spikes
    2. New setting in System Conf​ig menu: "CAT RU and RD" specifies Absolute or Relative commands
    3. CAT RU and RD can now do a relative up/down shift matching N1MM keyboard RIT adjustment
    4. Now TX indication bar appears under the top left character of display (A or B) on SSB microph​one transmit
    5. Band Configuration screen now re-coded as menu-driven table editor; and removed from Hardware tests menu
    6. Bug fix: CAT FW; returned FW000; always when in CW mode, not the correct bandwidth
    7. Bug fix: Redrawing CW Offset and Sidetone frq on CW config screen in terminal corrupted display
    Release notes & download
  27. Version 1_02_000 Released May 2, 2025 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. SSB modes added (USB and LCB), with CESSB, TX Equalization, Mic AGC, VOX, etc
    2. Rationalization of menus, grouped into CW, Digi and SSB submenus
    3. Added up to two more USB Virtual COM serial ports (configurable)
    4. LCD versions of AF, RF​, Image, LPF, Test ADC I/Q sweeps (miniature graph on LCD)
    5. New function PA mod. test to check operation of amplitude modulator
    6. Diagnostics screens are now available on the LCD interface too
    7. Now remembers previous menu location on ALL menus regardless of nesting level
    8. Add way of forcing factory reset, press Menu (left) button during power-up
    9. Change TX color in diagnostics screen from red to blue, to avoid confusion since red things are errors
    10. Added CAT LC command to retrieve LCD contents
    11. Added​ CAT commands SA (AGC meter), SM (S meter), PC (Power meter), SW (SWR meter)
    12. Added CAT command SS (get/set SSB input source) 13: Bug fix: PTT P did not work properly 14: Bug fix: Incorrect PA voltage display on the Diagnostics screen
    Release notes & download
  28. Version 1_00_027 Released Aug 22, 2024 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes

    (same as 1_00_026)

    1. 20m Factory Reset Band Cfg sweep start ​freq changed to 6,500,000; 17m now 13,000,000
    2. Slower shut-down and start-up procedure for​ 5V supply
    3. Support for additional factory test procedures
    Release notes & download
  29. Version 1_00_026 Released Aug 10, 2024 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Bug fix: VFO tune rate defaulted to 10M/1M/10k/10k digits; should default to 1k/500Hz/100Hz/10Hz
    2. ​Bug fix: Change default VFO mask to all three (A/B/Split) to match previous behavior
    3. Bug fix: Functionality 'N' to copy A->B and 'D' to copy 'B->A' didn't work (op man page 14)
    4. "Tune SWR" moved to top of Hardw​are tests menu instead of GPS Viewer
    5. Improvements to "Tune SWR" tool (start in current band; allow freq tuning)
    6. Bug fix: LCD message editing was broken in 024/025
    7. When beacon mode is enabled, return to usual VFO frequency when not TXing on beacon freq
    8. Reduce clicks on power up, power down, band change
    Release notes & download
  30. Version 1_00_025 Released Aug 6, 2024 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes

    (same as 1_00_024)

    1. Bug fix: Hang with msg "Initializing audio system" in some cases on firmware upgrade to 024
    2. Bug fix: Prevent initial CW decoder buffer being filled ​with S-meter characters!
    3. Bug fix: CW-R now works properly (when enabled, is in LSB mode, automatically)
    4. Bug fix: During RIT mode, left rot enc button functions not working (power down, band & mode change)
    5. Bug fix: Diagnostics screen 160m TX doesn't work until yo​u change bands and come back to 160m
    6. Bug fix: Audio in diagnostics sounded awful if you were in Digi mode when you opened it
    Release notes & download
  31. Version 1_00_024 Released Aug 6, 2024 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Added many more CW filters and CW filter options in the filter menu
    2. Bug fix: Display corruption on exiting system config menu on the LCD
    3. Add BK, AS, KA as prosigns, and other pun​ctuation
    4. Change "IQ Mode": now radio functions normally, but raw I & Q are streamed out not demod audio
    5. Add VFO menu with UI masks for VFO Mode, VFO tune rate and RIT tune rate
    6. Bug fixes and improvements in display and beh​avior of RIT and decoded CW
    7. Bug fix: fix incorrectly swapped tip/ring meaning in Straight key mode
    8. Switch off CLK2 carrier during key-up between Semi-QSK
    Release notes & download
  32. Version 1_00_023 Released Jul 31, 2024 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes

    (same as 1_00_​022)

    1. Bug fix: SWR and GPS tools were not accessible on the LCD/Knobs of the radio itself (erroneous me​ssage "Locked by terminal app").
    Release notes & download
  33. Version 1_00_022 Released Jul 31, 2024 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Bug fix: CAT KY when keyer speed is zero sends very fast; now just returns ? and does nothing
    2. Bug fix: CAT KY when transmit disabled for any reason incl practice mode, got stuck
    3. Bug fix: Playing a message memory when speed is zero se​nt very fast, now ignores
    4. Semi QSK settings: OFF, Auto, Contest, Custom dits, Custom decidits, Custom ms, new Custom val param
    5. Bug fix: LPF and SWR sweep didn't work for QMX+ 160m and 11m when band limits are enabled
    6. New sys config setting "RX outside band" (d​efault OFF); when off, restricts rx to in-band
    7. CW Offset range now 400-999
    8. Added new filter sub-menu, with CW filter selection and "Auto-offset/tone"; 300/500 Hz filters at various centers
    9. Bug fix: now lock buttons/knobs to prevent corruption while running terminal apps RF Sweep etc
    10. Bug fix: Prevent LCD frequency changes while terminal apps like RF Sweep are active
    Release notes & download
  34. Version 1_00_021 Released Jul 25, 2024 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Japan limits setting renamed "Band Limits": "ITU Region 2" (default), Japan, or None
    2. CAT: Implement KS command to Get/Set CW keyer speed
    3. CAT: Implement KY command to send text via CW transmission
    4. CAT: Implemented Set command for RT: RT1; to enable R​IT mode, RT0; to disable it
    5. CAT: Implemented RC (RIT Clear) command RT; to disable RIT mode
    6. Click "Tune" rotary encoder knob in RIT mode to move RIT cursor one character right
    7. Test ADC I/Q screen now has band +/- so can run for all bands
    8. Force display of battery icon, if TX is disabled due to supply voltage being out of range
    9. Diagnostics screen now shows the REASON for not transmitting, if it produces no RF
    10. I2C bus speed increased from 400kHz to 1MHz
    11. Bug fix: Implemented semi-QSK properly (8 dit lengths delay like in QCX)
    12. Bug fix: CAT: RD0; and RDU; Set commands made RIT zero but this wasn't displayed
    13. Bug fix: CAT: Now calling RD or RU CAT Set commands causes the UI to enter RIT mode
    14. Bug fix: CAT: Proper behaviour when CAT RIT commands are called and LCD is in menu mode
    15. Bug fix: If RIT is non zero when leaving menu, RIT mode wasn't re-entered
    16. Bug fix: Incorrect characters on LCD in SWR tool, when changing band 160 -> 80m etc
    17. Bug fix: Preset number was missing on t​he display, when selecting a preset frequency
    18. Bug fix: Settings reload only done on exiting Configuration menu (some menus accessed elsewhere)
    19. Bug fix: Power supply range TX disabling didn't work properly
    20. Bug fix: Battery icon froze when CW decoder enabled
    21. Bug fix: RX PTT was not activated after Band Config edit until keyed
    22. Bug fix: Test ADC I/Q screen was corrupt on first opening, needed R to refresh
    Release notes & download
  35. Version 1_00_020 Released Jul 11, 2024 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. New Test ADC I/Q tool shows baseband I/Q samples, aiding diagnostics
    2. Add 20dB of attenuation in earphones when in Digi mode (equalize volume to CW)
    3. Remove the experimental "SuppressThump" setting which is now always on
    4. C​onfigure AGC defaults on factory reset (or new installation)
    5. Bug fix: Display leftovers on GPS display on LCD
    6. Bug fix: RF, AF and Image Sweep tools didn't work unless in VFO Mode A already
    7. Bug fix: Selecting a preset did not change the LPF selection, only the​ VFO
    8. Bug fix: LPF and SWR sweep screens broke if not all bands were enabled
    9. Bug fix: CAT bug, remove \0 character in AG; command response
    10. Bug fix: CAT bug, in IF command (1 character too long)
    11. Bug fix: CAT bug, remove \0 character in TM; command response
    12. Bug fix: Change minimum frequency from 3.2 MHz to 1.5 MHz
    Release notes & download
  36. Version 1_00_019 Released May 20, 2024 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Added QMX+ 160-6m to list of options at first power-up or after factory reset
    2. New CPU Monitor utility i​n the System menu in the terminal
    3. System configuration "GPS Source" selects paddle port or QLG3 as GPS source in QMX+
    4. System configuration "Real Time Clock" selects hardw​are CR2032 RTC in QMX+ or the QMX software clock
    5. Bug fix: occasionally hanging LCD updates during rapid frequency changes
    Release notes & download
  37. Version 1_00_018 Released May 1, 2024 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Bug fix: date for Decembe​r in GPS was called "DEV", should be "DEC"
    2. Bug fix: GPS date display in terminal was one month out
    3. Bug fix: On selecting factory reset, the LCD did not update to show the "Reset..." message
    4. Expanded ​Band Config screen to 16 columns
    5. New version available at power up which populates Band Configuration for the 60-15m version
    6. New menu item in Audio "Suppress thump" to enable click suppression logic
    Release notes & download
  38. Version 1_00_017 Released Feb 16, 2024 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Bug fix: '5351 sy​nth code for setting TX params could lock up in some circumstances
    2. New LPF Sweep application in the terminal
    3. Added S-meter
    4. Added AGC implementation and supporting configuration menu para​meters
    5. Bug fix: Parameter corruption (incl IQ Mode setting lost) in Digi config menu
    Release notes & download
  39. Version 1_00_016 Released Feb 10, 2024 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes

    (same as 1_00_015)

    1. Bug fix: Was​ returning to the last saved band frequency after a sent message
    2. Bug fix: Power/SWR meter not shown in message memory transmissions
    3. Bug fix: Sideband selection and CW-R selection not properly cached, leading to wrong sideband reception
    4. Bug fix: dot, double-dot and underline of top left (VFO A/B) character not shown when WSJT-X transmits
    5. Bug fix: Power/SWR meter menu update interval parameter editing not working properly
    6. Bug fix: Attempted fix for what seems to be a new extra dits affecting I​ambic B
    7. Bug fix: Battery icon showed incorrectly, during standalone beacon mode (should not be shown)
    8. Bug fix: WSPR beacon display not cleared properly between waiting stage and running stage
    Release notes & download
  40. Version 1_00_015 Released Feb 9, 2024 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Bug fix: CW timing glitches resolved.
    2. Removed unused S-meter step parameter.
    3. Remembers frequency by band.
    4. Re-arrangement of EEPROM config - automatically performs factory reset on upgrade to 1_00_015.
    5. Bug fix: if you tuned below 3.2MHz it locked up; now added minimum 3.2MHz frequency to avoid this
    6. Bug fix: PTT output port wasn't enabled; now PTT output is enabled.
    7. Bug fix: When in Japanese band limits mode, message sending did not work.
    8. Bug fix: It allowed you to send message when you're in Digi mode!
    9. Bug​ fix: Some of the Message presets got truncated, due to EEPROM page boundary issue.
    10. Bug fix: when message editing, left button on a space didn't move right (if the space was really a null).
    11. Bug fix: substantial reduction in keying to sidetone latency, and sped up sidetone amplitude shaping 10x.
    12. Bug fix: when message editing, on exit of a long message it didn't scroll back to the beginning by itself.
    13. Moved CW-R parameter to the System config menu, alongside Sideband selection.
    14. Increased gain control range to 200dB.
    15. Added setting "Audio attenuation" 0, 20, 40, 60, 80 or 100dB to move the audio gain window down.
    16. Added setting "Mute at min. vol.", if YES means you get total silence when at minimum volume.
    17. When SWR protection triggered, sidetone is silenced as well as power output, so you know it happened.
    18. During WSPR beacon mode, if SWR protection is triggered it shows an S in the bottom right hand corner.
    19. Bug fix: WSPR beacon now works correctly from start-up and from menu-enabling and everywhere else.
    20. Added real time clock Time setting menu in Beacon and System menus.
    21. Added CAT command TM for get/set of real time clock.
    22. Bug fix: TX shift threshold in Digi menu was only two digits but needs to contain number 500 (by default).
    23. Bug fix: SWR protection kicked in sometimes at very low powers at the end of transmissions etc.
    24. Bug fix: Incorrect cursor position on LCD when editing byte values such as Sidetone volume.
    25. Bug fix: After being in SWR test mode, no keying was possible until you re-entered and exited menu.
    26. Bug fix: a new LCD driver from ​scratch, prevents screen corruption when decode, battery, clock etc all on.
    27. Bug fix: If you plugged in GPS while in the menu, GPS auto-protection wasn't triggered.
    28. Bug fix: Opening terminal apps (Band Config, hardware diagnostics etc) blocked TX until enter/exit menu.
    29. Moved Battery and Power/SWR meter configurations to their own sub-menu.
    30. Added Power meter interval and TX->RX hang time configurations.
    31. Recall last used top level menu item; next time you enter the menu system it goes back to same place.
    32. Bug fix: First clockwise click of encoders got ignored.
    Release notes & download
  41. Version 1_00_014 Released Dec 13, 2023 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Bug fix: Si​mple bug fix to 1_00_013 which​ needed factory reset every power cycle!
    Release notes & download
  42. Version 1_00_013 Released Dec 12, 2023 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Bug fix: CW-R didn't work.
    2. Bug fix: CAT MD command set didn't work (change mode command).
    3. CW-R and Sideband selection are now part of the saved radio state (not just menu parameters).
    4. SWR protection and SWR on transmit display are disabled if power is below 0.5W.
    5. Bu​g fix: Make sure SWR protection is disabled when in Practice mode.
    6. Bug fix: Diagnostics screen shouldn't display SWR when in Practice mode.
    7. Add "CW Offset" parameter to the Keyer menu; works between 600-800 Hz only.
    8. Bug fix: Sidetone frequency is now implemented (100-999Hz).
    9. "ENABLE"/"DISABLE" changed to "ENABLED"/"DISABLED" which is less confusing.
    10. Bug fix: CAT command MD7 ​didn't properly set the mode to CW-R (reported mode 6).
    11. Bug fix: Solve keyer glitches.
    12. Bug fix: Hyperactive SWR protection: now only allow if not already in some kind of practice mode.
    13. Bug fix: SWR protection mistakenly set on exiting message sending if in key-down.
    Release notes & download
  43. Version 1_00_012 Released Dec 5, 2023 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Fix to volume control erratic behavior.
    2. Prevent audio over-drive causing sudden distortion.
    3. Add "Audio" menu.
    4. Ad​justable audio gain in steps of 0.25, 0.5, 1, 2 or 4 dB.
    5. Sidetone volume can be applied absolutely or relative to audio volume.
    6. Adjustable sidetone volume works properly.
    7. Bug fix: There was silence if you started up on 80m band.
    8. Bug fix: Custom splash screen is now working.
    9. CAT command MD now sets/returns 9 for FSR (FSK Reverse) in LSB & Digi mode
    10. CAT command FW now returns 3200 when ​in Digi mode (FSK)
    11. CAT command AG now operates consistent with TS-480 documentation (AG; still works too)
    Release notes & download
  44. Version 1_00_011 Released Nov 29, 2023 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Add band version selection in system menu and on first power-up
    2. The CAT MD command now supports 3 (CW), 6 (FSK) and 7 (CWR)
    3. Added advanced settings menu - use with caution - normal​ly leave all enabled!

    3a. "Mod. high in RX" - sets PA modulator high in RX mode which should improve RX performance 3b. "Normal 5ms shape" - when disabled, shape is done 33x faster (0.15ms rise/fall) 3c. "20/80m BPF TXswap" - swaps 20m BPF and 80m BPF on transmit (see Rev 2 PCB issue )

    1. CAT FW comman​d now returns 0000 for SSB and 0300 for CW (was 3200 always) NOTE: After upgrade from an earlier version, please check the new settings items and make sure they are all set to ENABLE and that the band version is set correctly to match your hardware.
    Release notes & download
  45. Version 1_00_010 Released Sep 30, 2023 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Single character battery voltage option instead of battery image
    2. Initialization sequence on display so if stuck ​anywhere we'll know where
    3. PA voltage is always on in diag screen and green/red to indicate correct range
    4. Power and SWR added to diag screen
    5. Pwr and SWR meter on display; controlled by menu entry in Display/c​ontrols menu
    6. Bug fix: Battery now shown correctly at power-up, and when CW decoding disabled
    7. New protection menu, with SWR protection enable and threshold
    8. Supply voltage min/max protection including warn or optional TX inhibit
    9. SWR sweep added to terminal applications
    10. SWR Tuneup screen on QMX LCD
    Release notes & download
  46. Version 1_00_009 Released Aug 5, 2023 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Just a recompile ​of 1_00_008 because it​ seems some items didn't get compiled in
    Release notes & download
  47. Version 1_00_008 Released Aug 5, 2023 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Improved PWM control loop for the buck converter power supplies
    2. Bug fix: When decoding transm​itted CW it was written to wrong parts of the LCD
    3. Bug fix: CW Beacon was at the VFO frequency, not the beacon frequen​cy
    4. Bug fix: Stored message sending didn't work
    5. Only run the CW decoder in CW mode
    6. Swap the dit and dah naming in the diagnostics screen for consistency
    7. Do not allow mode change during transmit
    Release notes & download
  48. Version 1_00_007 Released Aug 1, 2023 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Add Keyer menu configuration "GPS protection" to enable auto protection
    2. Make GPS protection auto-practice a bit less paranoid
    3. Bug fix: Fix the WSPR/CW/FSKCW beacon functionality
    4. Bug fix: Fix the applicable CAT Q1, Q2 etc commands
    5. ​Add mode indicator character, row 1, column 12
    6. Digimode transmit status indicator, underlines VFO A symbol
    7. Fix string editing (messages editing) in the LCD/buttons
    8. When editing messages, horizontal scroll when message longer than a screen width
    9. Bug fix: Practice mode indicator not shown if it is set at power-up
    10. Bug fix: Keyer Swap reversed compared to QCX
    11. Bug fix: Practice mode indicator not shown in Digi mode
    12. Bug fix: On digi, carrier t​ransmission started on PTT not on incoming audio
    13. Improve LCD write speed by a factor of approx 50
    14. Bug fix: When battery indicator enabled, CW decode could corrupt top row
    Release notes & download
  49. Version 1_00_006 Released Jul 27, 2023 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. New GPS viewer screen in termin​al, some data also available on the LCD
    2. New hardware diagnostics screen in terminal, replaces T​X Test screen
    3. Bug fix: CW message memories now work
    4. Bug fix: Some settings such as USB/LSB did not work until power cycled
    Release notes & download
  50. Version 1_00_005 Released Jul 20, 2023 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Big Bug fix to 1_00_004: WSJT-X stoppe​d transmitting after a second or s​o
    2. Bug fix: RX frequency offset not set/reset after CW/Digi mode change
    Release notes & download
  51. Version 1_00_004 Released Jul 19, 2023 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Menu system rewrite, consis​tent between terminal and UI
    2. Removed Tx/Rx Param 1/2 from Band Config screen and ​hard code to 0 and 1 resp.
    3. Fix CW decoder
    Release notes & download
  52. Version 1_00_003 Released Jul 9, 2023 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. Amended defaults of Band Co​nfiguration screen to suit revised assembly manual including #2 mod
    2. Increased version string size f​rom 7 to 8 to properly display firmware version on terminal screen
    Release notes & download
  53. Version 1_00_002 Released Jun 14, 2023 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes
    1. RF Envelope shap​ing and sidetone shaping, key-click removal
    2. Larger USB buffer avoids terminal overflow with this fast CPU
    3. Fix RIT and VFO A/B/Split operation
    4. Fix backlight toggle on left button triple click
    5. Fix​ tune rate cursor (erased by battery icon update)
    6. Add Other menu option for firmware update
    Release notes & download
  54. Version 1_00_001 Released May 31, 2023 First seen Sep 7, 2026

    Source: qrp-labs.com

    Show release notes

    Initial alpha firmware release for QMX.

    Release notes & download

Watch the QMX for updates

Get an email the moment QRP Labs publishes new firmware. Just your email — no account or password needed.