v1.01 is not the latest firmware for the Kenwood TH-D74: the current version is v1.11 (August 26, 2020). Go to v1.11
In short — summary by updatemystuff.com
Fixes RX History storage and audio recording issues in DV/DR mode
- Fixed RX History storage in DV/DR mode
- Fixed receiving audio recording in DV/DR mode
Written from Kenwood's release notes, which are printed in full below.
Was this useful? Thanks.
What's in this update
The following symptoms are revised.
- In DV/DR mode, RX History may not be stored correctly.
- In DV/DR mode, receiving audio might not be recorded.
Applicable models/units :
The firmware updating program is applicable for the following models/units.
Models: TH-D74A, TH-D74E Serial numbers: From S/NO.B68xxxxx through S/NO.C09XXXXX approx.
Notes
You can find the serial number imprinted on the rear panel after removing the battery.; It consists of an 8-digit number beginning with "S/NO."
: You can check the firmware version of your TH-D74A/E by accessing Menu No.991. The firmware version appears in the LCD display.
Operating Environments
- Operating System (OS)
Windows ® 8.1 (32-bit or 64-bit)
Windows ® 10 (32-bit or 64-bit)
Notes
This software is designed to run on the above operating systems.
Applicable operating systems are subject to change without notice due to the end of the technical support by Microsoft Corporation or change of the product specifications.
The .NET Framework 4.6 which is available for download from Microsoft download center must also be installed. (Windows ® 10 users do not need to install the .NET Framework.).
- Processor
Faster than the recommended CPU for each OS.
- System Memory (RAM)
Larger than the recommended System Memory for each OS.
- Free Hard Drive Space
Larger than the system Hard Drive Space for each OS.
- Peripheral Devices
A display with resolutions higher than VGA (640 x 480)
A keyboard and a mouse, or other pointing devices.
USB 2.0 interface.
Attention
If you do not want to lose user data, save the data using the Memory Control Program MCP-D74 before updating the firmware and write the data back after updating the firmware.
Turn the transceiver OFF before connecting it to a PC.
You cannot connect the TH-D74A/E to a PC COM port via an RS-232C cable.
Notes on usage
Users are prohibited to assign, rent, lease, redistribute, or resell the software.
Users are prohibited to revise, change, translate, merge, de-compile, or reverse engineer the software.
JVCKENWOOD Corporation does not warrant that quality and functions of this software comply with each user's purpose of use of this software, and unless specifically described in this document, JVCKENWOOD Corporation shall be free from any responsibilities to any defects and indemnities to any damages or losses.
Selection and installation of this software shall be done by the user's own designation.
The user shall take full responsibility for the use and effects of this software.
JVCKENWOOD Corporation shall be free from any responsibilities for any incidental losses or damages, such as missing communications or a call opportunity, caused by a failure or performance error of this software.
JVCKENWOOD Corporation shall own all copyrights and other intellectual properties for the software and all manuals and documents attached to the software.
The user shall be allowed to use, not to resell, the software by obtaining a license from JVCKENWOOD Corporation.
While the media on which the software is stored is possessed by the user, the ownership for the software itself shall be reserved for JVCKENWOOD Corporation.
Installation:
Extract the downloaded file "TH-D74_V111E.zip" into a designated folder.
In the designated folder, a folder labeled "TH-D74_V111E" will be created.
In the folder labeled "TH-D74_V111E", two files "TH-D74_V111_e.exe" and "TH-D74_e.chm" are automatically created.
Updating:
- Start the program by double-clicking "TH-D74_V111_e.exe" icon.
- Connect the transceiver's USB port to your PC's USB port using a Micro-USB cable, and select the COM port you will use by following the Help file.
- Proceed firmware updating by following the explanations in the dialog boxes.
Uninstalling:
- Delete the folder labeled "TH-D74_V111E" manually using the Explorer or an alternative method.
- This software does not modify the system registry parameters or system folder.
If you agree with the details listed above, click the following link to download the firmware updating program.
(The latest version includes all previous updates.)
TH-D74 Firmware Update Version 1.11 (August / 2020)
TH-D74_V111E.zip : 7.65MB download
The download is currently suspended due to technical reasons. Sorry for inconvenience.
If you wish to update your TH-D74A/E, please ask your local service center, or click here to contact us.
- KENWOOD Customer Support (Japan HQ) will be closed from December 26, 2024 to January 5, 2025. Inquiries received during this period will be answered sequentially from January 6, 2025.
-->
- KENWOOD Customer Support (Japan HQ) will be closed from August 9, 2024 to August 18, 2024. Inquiries received during this period will be answered sequentially from August 19, 2024.
-->
Windows is a registered trademark or trademark of Microsoft Corporation in the United States and other countries.
.NET Framework is a registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Global Site
updatemystuff.com never hosts firmware files — always download from the official source.
Get it from KenwoodWatch the TH-D74 for updates
Create a free account and get an email the moment Kenwood publishes new firmware.
Create account & watch